Turkce
+90 (216) 557 97 97
 

Başlık



HealFusion S7 Syringe Pump

 

  • Product Application ICU, Operating room, Pediatrics Department
  • Waterproof grade: IPX3
  • Dual-CPU design: to ensure system security
  • Performance requirements
  • Injection control parameters
  • Injection rate range (0.011500)ml/h
  • Preset time:00:00:01-99:59:59h:m:s
  • Injector automatically identification: 2ml, 5ml, 10ml, 20ml, 30ml,50/60ml, Built-in more than 30 kinds of common injector brand specifications, custom injector calibration.
  • Injection accuracy ± 2% Mechanical accuracy ± 0.5%
  • Quick start: Injections quick start automatically to eliminate delivery delays.
  • Automatically push and manually push, BOLUS Rate (0.1 ml/h~ Injector Max. Rate)
  • Automatically push, the preset value 0.1ml~5ml, step value 0.1ml.
  • Keep Vein OpenKVO):When injection is completed
  • automatically enter KVO mode, KVO feature can be turned off. KVO rate ofinjection is adjustable and the range is (0.1~5.0), ml/h, step value 0.1ml.
  • Online Pressure Supervision (DPS): With real-time detecting and
  • information displayed piping online pressure during injection. Adjustable occlusion pressure alarm threshold value is 11 levels. When injector pipe plug, infusion pump stopped working with a sound and light alarm displaying on screen.
  • Occlusion Pressure Release (Anti-Bolus): When injector pipe plug,
  • syringe pump automatically releases line pressure avoiding harm to the patient by BOLUS.
  • Anti-siphon: Prevents liquids outflow during the pause
  • Battery (Fully charged, Injection rate 5ml/h):≥360 minutes
  • Charging time: ≤240 minutes; Battery Life time ≤ 10 years
  • Event Records: 2000. Automatically records the boot operation and alarm information, including injection beginning, injection completed,infusion rate change, injection volume and alarm information.
  • 3.2.12 Alarm: High, Medium and Low sound and light alarm, 9 levels adjustable Beep sound.
  • Alarm type: AC power failure alarm, DC power outage alarm, Low battery alarm, Battery death alarm, Forget reminder alarm, Injection nearing completion alarm, Injection complete alarm, Syringe empty alarm, Flow rate alarm, Syringe off alarm, System exception alarm
  • Input/output interface: RS232 communication data transmission
  • & nurse call. Connecting DOCK transfusion management system, installing the wireless module for wireless monitoring
  • Pump transfusion station by inserting a DOCK with guide
  • grooves between stacked pumps.
  • Syringe Modes: Rate mode, Preset time mode, Time mode
  • Screen: 3.5 " resistive touch screen, the brightness of 1-9
  • adjustable, factory default 5 levels.
  • Information display: syringe, cumulative volume, preset volume,
  • threshold pressure and current pressure, alarm, syringe brand and specifications, the power state, date, time.

 

 