Turkce
+90 (216) 557 97 97
 

Başlık



HealFusion I7 Infusion Pump

 

  • ICU, Operating Room, Pediatrics, Emergency, Cardiovascular and other
  • departments for precise control
  • Waterproof grade: IPX3
  • Dual-CPU design: to ensure system security
  • Infusion rate (0.01~2000) ml/h
  • Infusion accuracy ± 5%.
  • Flow compensation feature: automatic compensation for infusion
  • line collapse loss of fluid volume
  • Automatically push and manually push, BOLUS Rate(0.12000) ml/h.
  • Automatically push, the preset value 0.1ml~5ml, step value 0.1ml.
  • When injection is completed automatically enter KVO mode, KVO feature can be turned off. KVO rate of
  • injection is adjustable, and the range is (0.1~5.0)ml/h, step value 0.1ml.
  • With real-time detecting andinformation displayed piping online pressure during injection. Adjustable occlusion pressure alarm threshold value are 11 levels. When injector pipeplug, infusion pump stopped working with a sound and light alarm
  • displaying on screen.
  • Upstream Obstruction Warning: When the infusion line liquid
  • enter a partial blockage, infusion pump stopped working with a sound andlight alarm displaying on screen.
  • Bubble Detection: A single bubble alarm for 25ul, 100ul, 250ul.
  • Cumulative bubble alarm adjustable for 300ul/15min, 500ul/15min.
  • Battery (Fully charged, Infusion rate 25ml/h):≥360 minutes;
  • Charging time: ≤240 minutes; Battery Life time ≤ 10 years
  • Event Records: 2000. Automatically records the boot operation and alarm information, including injection beginning, injection completed,infusion rate change, injection volume and alarm information.
  • Alarm: High, Medium and Low sound and light alarm, 9 levels
  • adjustable Beep sound.
  • Alarm type: AC power failure alarm, DC power outage alarm, Low
  • battery alarm, Battery death alarm, Forget reminder alarm, Infusion
  • nearing completion alarm, Fluid completed alarm, Door open alarm,
  • Bubble detection alarm.
  • Input/output interface: RS232 communication data transmission
  • & nurse call. Connecting DOCK transfusion management system, installing
  • the wireless module for wireless monitoring
  • Pump transfusion station by inserting a DOCK with guide
  • grooves between stacked pumps.
  • Infusion Modes: Rate mode, Dose conversion mode, Preset time
  • mode, Time mode
  • Screen: 3.5 " resistive touch screen, the brightness of 1-9
  • adjustable, factory default 5 levels.
  • Information display: infusion, cumulative volume, preset volume,
  • threshold pressure and current pressure, alarm, infusion brand and
  • specifications, the power state, date, time.
 